View Projects

Public

Lake Tahoe Fire Station 11

Incline Village, NV

Gary Davis Group was selected by the North Lake Tahoe Fire Protection District to investigate the cause of cracking in the slab of their relatively new station equipment bays. GDG led a team including a national expert. The slab was surveyed and the cracks mapped to establish patterns. The original construction drawings and specifications were reviewed as well as the special inspection logs. After a thorough review, GDG prepared a report and presented findings to the District Board.